For container terminals, the most relevant alternative fuels include hydrogen, LNG and several types of biofuel, but they are fundamentally different energy carriers. Hydrogen can be used in fuel cells or adapted internal-combustion engines and can be produced with very low lifecycle emissions when renewable electricity is used. LNG is natural gas cooled to approximately −162°C so that it becomes liquid, making it considerably more compact than gaseous natural gas. Biofuels are a broad category that includes biodiesel/FAME, HVO, bio-methanol, bio-LNG and other fuels produced from biological feedstocks. Their characteristics vary substantially. Some, particularly HVO and certain biodiesel blends, can behave similarly to conventional diesel, while hydrogen and LNG require much more specialised storage and fuel systems. Reference: EMSA – Sustainable Shipping: Alternative Sources of Power
Energy density determines how much usable energy can be stored in a given quantity or volume of fuel. This is particularly important for terminal equipment because vehicles, cranes and other mobile assets have limited space for fuel storage. Hydrogen has excellent energy density by mass, but relatively poor volumetric energy density, even when compressed or liquefied. LNG has considerably better volumetric energy density than compressed natural gas, but still requires more storage volume than conventional diesel for an equivalent amount of energy. Biofuels generally have energy densities closer to conventional liquid fuels, although biodiesel contains somewhat less energy per unit volume than petroleum diesel. Consequently, fuel choice affects tank size, operating range, refuelling frequency and potentially equipment availability. Energy density therefore needs to be considered alongside storage technology, not simply as a property of the fuel itself. Reference: U.S. Department of Energy – Fuel Properties Comparison
Hydrogen is unusual because its energy density depends strongly on whether it is considered by mass or by volume. By mass, hydrogen contains substantially more energy than conventional liquid fuels. By volume, however, gaseous hydrogen occupies a very large amount of space, even when compressed. Liquefying hydrogen improves volumetric density but requires extremely low temperatures, around −253°C. LNG, by comparison, is stored at approximately −162°C and has a much higher volumetric energy density than compressed hydrogen. Diesel remains highly advantageous in terms of compact onboard energy storage because it is a dense liquid at ambient conditions. For terminal equipment, this means that switching from diesel to hydrogen may require significantly larger or more sophisticated fuel-storage arrangements, particularly where long operating cycles and limited refuelling opportunities are involved. Reference: U.S. Department of Energy – Fuel Properties Comparison
Hydrogen can principally be stored as compressed gas or as a cryogenic liquid. Compressed hydrogen is stored in high-pressure tanks, allowing considerably more hydrogen to be contained in a given volume than at atmospheric pressure. Liquefied hydrogen is cooled to approximately −253°C, reducing its volume substantially but creating demanding cryogenic-storage requirements. The choice between the two approaches depends on the application, required range, available space and refuelling infrastructure. For container terminals, compressed hydrogen is generally easier to conceptualise for shorter-range equipment, while liquid hydrogen could become relevant where high energy demand and longer operating periods justify the additional complexity. Both approaches require dedicated storage systems, controls and safety measures. Hydrogen's very low density and broad flammability range mean that storage cannot simply be treated as a conventional diesel-tank replacement. Reference: U.S. Department of Energy – Fuel Glossary: Liquefied Hydrogen and LNG
Hydrogen presents several safety characteristics that differ from conventional liquid fuels. It has a very broad flammability range in air and requires relatively little energy for ignition. Hydrogen is also extremely light, so released gas tends to rise rapidly rather than remain close to ground level. This can be advantageous in some open environments but creates specific requirements for ventilation, detection and equipment layout. Hydrogen can be stored under high pressure or at cryogenic temperatures, introducing additional hazards associated with pressure and extreme cold. EMSA notes that hydrogen's flammability properties exceed those of natural gas, making appropriate detection, ventilation, isolation and emergency procedures particularly important. For container terminals, the safety assessment therefore needs to consider not only the fuel itself but also storage locations, vehicle movements, maintenance activities and potential collision or equipment-damage scenarios. Reference: EMSA – Safety of Hydrogen for Use in Ships
The fundamental issue is hydrogen's low volumetric energy density. Hydrogen contains a large amount of energy per kilogram, but its molecules are extremely light and therefore occupy considerable volume when stored as a gas. Compression reduces the volume substantially, while liquefaction reduces it further, but both solutions require additional equipment and energy. Even liquefied hydrogen requires specialised cryogenic tanks and insulation. Diesel, in contrast, is a dense liquid that can be stored relatively simply in compact tanks at ambient temperature and pressure. For a container terminal, this difference can directly influence vehicle range, tank size, payload considerations and the location of refuelling infrastructure. A hydrogen-powered terminal tractor, for example, may require a substantially different fuel-storage architecture from a diesel-powered equivalent, even if the two vehicles have comparable power requirements. Reference: EMSA – Sustainable Shipping: Alternative Sources of Power
LNG is natural gas, consisting predominantly of methane, that has been cooled to approximately −162°C so that it becomes liquid. Liquefaction greatly reduces its volume compared with gaseous natural gas, making LNG practical for storage and transport. Its energy density by volume is lower than that of conventional diesel, however, so more tank volume is needed for an equivalent energy supply. LNG is also a low-flashpoint fuel, which means that its storage and handling require dedicated safety systems. The IMO's IGF Code establishes mandatory requirements for machinery, fuel-storage and fuel-distribution systems using LNG and other low-flashpoint fuels. For container terminals, LNG therefore offers a familiar combustion-based energy pathway but requires specialised tanks, fuel lines, ventilation, detection and safety arrangements that differ substantially from conventional diesel systems. Reference: IMO – International Code of Safety for Ships Using Gases or Other Low-Flashpoint Fuels
Natural gas becomes liquid at approximately −162°C under atmospheric pressure. Keeping LNG at this temperature allows its volume to be dramatically reduced compared with gaseous natural gas, making storage and transport practical. The challenge is that LNG therefore requires highly insulated cryogenic tanks and systems designed to handle extremely cold temperatures. Heat inevitably enters the storage system, causing some LNG to vaporise. This produces boil-off gas, which needs to be managed safely through appropriate system design and operating procedures. These characteristics distinguish LNG fundamentally from diesel and conventional liquid biofuels, which can generally be stored at much less demanding temperatures and pressures. At a container terminal, LNG storage therefore involves not only fuel tanks but also insulation, pressure management, gas detection, ventilation and specialised transfer equipment. Reference: U.S. Department of Energy – Fuel Glossary
LNG's principal safety characteristics arise from its cryogenic temperature and its flammability. A spill can create extremely cold liquid and surfaces, while vaporised natural gas can form a flammable mixture with air under appropriate conditions. LNG systems therefore require controlled storage, transfer and ventilation arrangements, together with gas detection and emergency shutdown capabilities. The IMO's IGF Code specifically addresses the arrangement, installation, control and monitoring of machinery and fuel systems using LNG and other low-flashpoint fuels. The Code is based on the principle that the fuel system should achieve an equivalent level of safety and reliability to conventional machinery. For a container terminal, this means LNG cannot be treated simply as another diesel substitute. Fuel-storage areas, refuelling zones, vehicle routing, maintenance procedures and emergency response all need to account for its physical properties. Reference: IMO – Gas and Low-Flashpoint Fuels Code
Biofuels are not a single fuel but a broad family of fuels produced from biological feedstocks or renewable organic material. For heavy-duty equipment, relevant examples include FAME biodiesel, HVO and other renewable diesel fuels. FAME is chemically different from conventional diesel and has specific properties relating to cold flow, oxidation stability and water handling. HVO, by contrast, is a hydrocarbon fuel whose properties can be much closer to conventional diesel. Bio-methanol and bio-LNG represent other pathways but involve different fuel-system requirements. This diversity matters because the term “biofuel” does not automatically tell an operator how a fuel behaves in storage, engines or handling systems. EMSA's marine biofuel work specifically examines fuels including HVO, FAME, bio-methanol and DME because their physical and chemical characteristics differ significantly. Reference: EMSA – Study on Safe Bunkering of Biofuels
Biodiesel generally contains less energy per unit volume than conventional petroleum diesel. The U.S. Department of Energy estimates that a gallon of B100 contains about 93% of the energy of a diesel gallon equivalent, meaning that more biodiesel may be required to deliver the same amount of energy. The difference is relatively modest compared with the volumetric penalty associated with hydrogen. For terminal equipment, however, the effect can accumulate over long operating cycles. A machine running on a high biodiesel blend may consume slightly more fuel to perform the same work, potentially affecting operating range and refuelling frequency. The actual effect depends on the blend and fuel quality. Lower-level blends can behave much more similarly to conventional diesel, making them easier to introduce into existing equipment and operating practices. Reference: U.S. Department of Energy – Biodiesel Blends
The biggest difference is that many biofuels are liquid fuels that can be stored using infrastructure broadly similar to that used for conventional petroleum fuels. This can make them considerably easier to introduce into existing terminal operations. However, “drop-in” does not mean that every biofuel behaves identically to diesel. Biodiesel, for example, can have different cold-flow, oxidation and water-handling characteristics, while compatibility requirements can vary with blend concentration and equipment. HVO is generally closer to conventional hydrocarbon diesel in its physical behaviour. Hydrogen and LNG are fundamentally different because they require high-pressure or cryogenic storage systems and dedicated safety arrangements. Consequently, biofuels often offer a lower physical barrier to adoption, while hydrogen and LNG introduce a much greater change in the terminal's fuel-storage environment. Reference: EMSA – Sustainable Shipping: Alternative Sources of Power
Biofuels can create storage considerations that are less prominent with conventional diesel. Biodiesel, particularly at high concentrations, can have poorer cold-temperature behaviour, and some fuels may be more susceptible to oxidation or water-related problems. The U.S. Department of Energy notes that high-level biodiesel blends can gel in cold temperatures and may present specific storage issues. Fuel quality is therefore important, as is selecting the appropriate blend for the operating environment. Storage tanks and associated equipment must also be confirmed as compatible with the intended fuel. These issues are especially relevant to container terminals operating outdoors through changing seasons, where temperature fluctuations and long storage periods can affect fuel performance. Proper fuel specification, tank management and monitoring can reduce these risks, but they should be considered part of the fuel's characteristics rather than treated solely as maintenance issues. Reference: U.S. Department of Energy – Biodiesel Fuel Basics
Many liquid biofuels present safety characteristics broadly comparable to conventional liquid petroleum fuels, although individual fuels and blends can differ. EMSA's assessment of marine biofuels found that existing regulations and procedures can often be applied, while also identifying the need for greater understanding and standardisation around biofuel bunkering. Hydrogen and LNG are more fundamentally different. Hydrogen has a very broad flammability range and can be stored under high pressure or at cryogenic temperatures. LNG is stored at approximately −162°C and is also a low-flashpoint fuel, requiring dedicated systems governed by specialised safety requirements. Consequently, biofuels can often be introduced with fewer fundamental changes to the safety environment, whereas hydrogen and LNG require a more extensive reassessment of fuel handling, detection, ventilation, emergency response and equipment design. Reference: EMSA – Study on Safe Bunkering of Biofuels
Yes. Hydrogen is an energy carrier rather than an inherently low-carbon fuel. Its environmental performance depends heavily on how it is produced. Hydrogen made using renewable electricity can potentially provide very low lifecycle greenhouse-gas emissions, while hydrogen produced from fossil fuels can have substantially higher emissions. This distinction is important when assessing hydrogen for container-terminal equipment because switching the machine itself does not automatically make the entire energy pathway low-carbon. EMSA identifies renewable or “green” hydrogen as having the potential for a near-zero-carbon solution on a well-to-wake basis, while also highlighting the need to expand production and distribution capacity. Consequently, terminals assessing hydrogen should examine not only the fuel's physical characteristics but also its production pathway, electricity source, upstream emissions and certification. Reference: EMSA – Sustainable Shipping: Hydrogen
Energy density is important, but it should never be the only comparison criterion. A terminal needs to consider at least five characteristics together: the amount of energy available, the physical state of the fuel, storage conditions, safety properties and compatibility with the intended equipment. Hydrogen may offer excellent energy per kilogram but requires specialised storage. LNG provides a more compact energy carrier than gaseous natural gas but requires cryogenic storage and low-flashpoint-fuel safety measures. Biofuels generally offer much greater compatibility with conventional liquid-fuel systems, but their energy content and physical properties vary by fuel and blend. The right comparison therefore depends on the operational application. A short-cycle terminal tractor, a long-running straddle carrier and a stationary generator may have very different fuel requirements even within the same terminal. Reference: DNV – Assessment of Selected Alternative Fuels and Technologies in Shipping
There is no universal best fuel because the three options solve different problems and impose different operational constraints. Hydrogen offers the possibility of very low operational and lifecycle emissions when produced from renewable sources, but its low volumetric energy density and demanding storage requirements are significant challenges. LNG can provide a relatively mature gaseous-fuel pathway with lower local air pollutant emissions than conventional fuel oil, but it remains a fossil fuel and requires cryogenic storage and specialised safety systems. Biofuels can be introduced relatively quickly, particularly where drop-in fuels are compatible with existing engines and fuel systems, but sustainable supply and fuel-specific characteristics remain important considerations. The appropriate choice therefore depends on the terminal's equipment, duty cycles, available infrastructure, environmental objectives and access to fuel. Reference: DNV – Shipping Fuel Choices: Navigating a Fragmented Landscape
Seeking reliable terminal services and scheduling? Terminal Tracker makes operations planning a matter of minutes. This powerful management system orchestrates assets efficiently for your next vessel. Integrated into your container terminal's IT landscape, it becomes core to operations. Plan shifts ahead, reserve vehicles and workforce. Adaptable to your yard and future needs, plug-and-play with your TOS, with straightforward installation by our Professional Services.
Terminal Tracker by Identec Solutions
Introducing an alternative fuel requires much more than installing a new fuel tank. The infrastructure depends strongly on the fuel. Hydrogen may require production or delivery connections, compression or liquefaction, storage, dispensers, safety systems and dedicated transfer equipment. LNG requires cryogenic storage, transfer systems, vapour management and gas detection. Biofuels are generally simpler because many liquid variants can use existing fuel-storage and distribution infrastructure, although compatibility and fuel-specific safety requirements still need to be checked. The terminal also needs to consider access for fuel deliveries, internal distribution, refuelling locations, emergency response, monitoring and maintenance. The scale of infrastructure should match expected fuel demand rather than simply the number of vehicles. A terminal with a large fleet and intensive operating cycles may require substantially different infrastructure from a smaller facility introducing alternative fuels gradually. Reference: U.S. Department of Energy – Hydrogen Delivery
Hydrogen can reach a terminal through several pathways, depending on demand, distance and local infrastructure. Gaseous hydrogen can be delivered through pipelines or compressed into tube trailers for road transport. Liquefied hydrogen can be transported in cryogenic tanker trucks and then stored at the terminal before being dispensed or converted back to gaseous hydrogen. A terminal could also produce hydrogen on site using electrolysis, provided it has sufficient electricity, water and suitable equipment. The choice is therefore not simply between “buying” or “producing” hydrogen. It is a question of designing an entire supply pathway from production to point of use. The U.S. Department of Energy identifies pipelines, liquefaction plants, trucks, storage facilities, compressors and dispensers as components of hydrogen delivery infrastructure. For terminals, demand volume and reliability requirements are particularly important when selecting between these pathways. Reference: U.S. Department of Energy – Hydrogen Delivery Infrastructure
A hydrogen refuelling installation normally includes several stages between fuel arrival and vehicle dispensing. Depending on the supply method, these can include a hydrogen delivery connection, storage, compression, pressure-management equipment, cooling or conditioning equipment, dispensing equipment and control systems. Gaseous hydrogen stations may use compressors and buffer storage to provide the pressure required for vehicle refuelling. ISO 19880-1 addresses the design, installation, commissioning, operation, inspection and maintenance of gaseous hydrogen fuelling stations. Its scope covers elements such as hydrogen delivery, liquid storage where applicable, compression, gaseous buffer storage, pre-cooling and dispensing. For heavy-duty terminal equipment, station design must also account for higher fuel demand and potentially much greater throughput than a passenger-vehicle station. Refuelling capacity therefore needs to be designed around the terminal's fleet size, duty cycles and operating schedule. Reference: ISO 19880-1:2020 – Gaseous hydrogen fuelling stations
Hydrogen storage should be positioned according to a site-specific risk assessment rather than simply choosing the location closest to the equipment. The design needs to consider separation distances, ventilation, access, vehicle movements, potential ignition sources, emergency response and interaction with other terminal activities. Storage may take the form of high-pressure gaseous systems or cryogenic liquid-hydrogen tanks, each creating different spatial and safety requirements. Refuelling areas also need to accommodate delivery vehicles or pipelines and provide safe access for maintenance. This can become challenging in established terminals where land is already heavily utilised, and traffic flows are tightly organised. ISO 19880-1 addresses hydrogen fuelling-station design and includes delivery, storage, compression and dispensing as connected parts of the station. In practice, hydrogen infrastructure should therefore be planned as part of the terminal layout rather than added as an isolated fuel installation. Reference: ISO 19880-1:2020 – Gaseous hydrogen fuelling stations
No. On-site hydrogen production is one possible supply model, not a requirement. A terminal can receive hydrogen through pipelines, compressed-gas tube trailers or liquid-hydrogen tankers. On-site production through electrolysis can nevertheless be attractive where suitable electricity and water are available and where a terminal wants greater control over supply. It can also reduce dependence on external hydrogen distribution networks that may still be developing. The disadvantage is that the terminal then becomes responsible for additional equipment, including the electrolyser, electricity supply, water treatment and associated hydrogen conditioning and storage. The appropriate model depends on demand, local energy prices, available land, reliability requirements and the maturity of regional hydrogen infrastructure. The U.S. Department of Energy describes both centralised delivery and distributed or on-site production as potential pathways, with the optimal arrangement depending strongly on where hydrogen is produced relative to where it is consumed. Reference: U.S. Department of Energy – Hydrogen Infrastructure
LNG requires dedicated cryogenic storage because it must remain at approximately −162°C to stay liquid at atmospheric pressure. A terminal installation therefore needs insulated storage tanks together with suitable transfer lines, valves, pumps and control systems. Depending on the configuration, vapour-management systems and equipment for handling boil-off gas are also required. LNG facilities additionally require gas detection, emergency shutdown systems, controlled access and appropriate safety zones. The infrastructure must be designed as an integrated system because the extremely low temperature and low-flashpoint characteristics of LNG affect both storage and transfer operations. EMSA's LNG bunkering guidance was specifically developed to help port authorities establish safe and environmentally appropriate bunkering arrangements. For a container terminal using LNG-powered equipment, the same principle applies: the storage installation must be integrated with the terminal's traffic flows, emergency procedures and operating environment rather than treated as a conventional diesel depot. Reference: EMSA – LNG Bunkering and Onshore Power Supply
LNG can be delivered through permanent infrastructure or mobile supply systems. Depending on the site and scale, supply may involve LNG tankers, road tankers, pipelines, storage facilities and dedicated transfer equipment. The appropriate arrangement depends on fuel demand, available land, required refuelling rates and the frequency of deliveries. Permanent infrastructure can support larger volumes and faster transfers but requires substantial investment and space. Mobile delivery can provide greater flexibility during early adoption or where demand is insufficient to justify a permanent installation. EMSA's guidance for LNG bunkering was developed specifically to help port authorities and administrations establish safe bunkering arrangements and harmonise requirements. Although bunkering guidance is primarily aimed at vessels, the underlying infrastructure principles — controlled transfer, suitable equipment, safety zones and emergency procedures — are also relevant when LNG is being supplied to terminal equipment. Reference: EMSA – LNG Bunkering & OPS
LNG storage capacity determines how much fuel a terminal can hold between deliveries and therefore how dependent operations are on the fuel-supply schedule. Too little storage can increase delivery frequency and expose the terminal to supply disruptions. Excessive storage, however, increases capital requirements and may create additional operational and safety considerations. LNG storage also has to account for heat entering the tank and the resulting generation of boil-off gas. The terminal therefore needs to consider not only the nominal tank volume but also expected consumption, delivery reliability, peak demand, storage duration and boil-off management. This is particularly important for container terminals because equipment utilisation can vary considerably with vessel schedules and yard activity. Storage should therefore be sized against actual operational demand and resilience requirements rather than simply against the average daily fuel consumption of the fleet. Reference: U.S. Department of Energy – Liquid Hydrogen Delivery
In many cases, yes, particularly for drop-in fuels such as HVO. EMSA describes the drop-in characteristic of biofuels as the ability to replace conventional petroleum-derived hydrocarbons without substantial modifications, and in some cases without modifications, to engines, tanks, pumps or supply systems. This can make biofuels significantly easier to introduce than hydrogen or LNG. However, the term “biofuel” covers several chemically different products, so compatibility cannot be assumed for every fuel or blend. FAME biodiesel, HVO, bio-methanol and other fuels have different physical and chemical characteristics and therefore different infrastructure requirements. Before switching, a terminal should confirm the fuel specification, equipment manufacturer's compatibility requirements, tank and hose compatibility, storage conditions and applicable standards. The infrastructure question is therefore much simpler for some biofuels than for hydrogen or LNG, but it still requires technical verification. Reference: EMSA – Alternative Sources of Power: Biofuels
The changes depend on the biodiesel concentration and the specific fuel. Existing diesel infrastructure may be usable, but tanks, pumps, seals, hoses and other components should be checked for compatibility with the intended blend. Storage management also becomes important because biodiesel can have different oxidation, water-handling and cold-flow characteristics from conventional diesel. A terminal operating in a cold climate may therefore need to pay particular attention to fuel specification and storage conditions. Blending arrangements may also be required if the terminal intends to use different concentrations rather than a single finished fuel. Unlike hydrogen and LNG, biodiesel does not normally require high-pressure or cryogenic infrastructure, which substantially reduces the physical changes needed at the terminal. Nevertheless, fuel quality management becomes an important part of the infrastructure because contamination, degradation or inappropriate storage can affect equipment reliability and fuel performance. Reference: EMSA – Safe Bunkering of Biofuels
Biofuels can generally be delivered through several supply models, including permanent port infrastructure, road tankers and, where relevant, ship-to-ship transfer. EMSA's guidance identifies port-to-ship, truck-to-ship and ship-to-ship as different bunkering supply modes, each with different advantages, disadvantages and maturity levels. For a container terminal, road-tanker delivery is likely to offer the greatest flexibility during an initial deployment because it requires less permanent infrastructure. Larger and more predictable fuel demand may justify dedicated storage and pipeline connections. The supply model should also account for delivery frequency, fuel volumes, traffic interference, simultaneous terminal operations and emergency response. A key advantage of liquid biofuels is that their physical handling requirements can be much closer to those of conventional fuels than those of hydrogen or LNG. However, fuel-specific procedures and equipment remain necessary, particularly for fuels with different toxicity, volatility or cold-flow characteristics. Reference: EMSA – Guidance for Safe Bunkering of Biofuel: Supply Modes
The required safety zones depend on the fuel, supply method, equipment and site-specific risk assessment. Biofuel bunkering guidance from EMSA, for example, identifies potential safety, security, hazardous and control zones around bunkering operations. It also recommends considering traffic restrictions, passing distances, emergency response and the interaction between bunkering and other activities. Hydrogen and LNG can require more stringent controls because of their gaseous or cryogenic properties and flammability characteristics. The important point for a container terminal is that a refuelling area cannot be designed independently of normal terminal traffic. Trucks, terminal tractors, reach stackers, cranes, maintenance vehicles and personnel may all pass nearby. Infrastructure planning must therefore establish where vehicles can operate, where personnel can enter, what activities can occur simultaneously and how the area can be isolated during an incident. Reference: EMSA – Guidance for Safe Bunkering of Biofuel: Port Requirements
Refuelling speed is critical because terminal equipment is productive only while it is available for work. A technically suitable fuel system can still create operational problems if vehicles need substantially longer refuelling periods or if too few dispensing points are available. Hydrogen stations, for example, require carefully sized compression, storage and dispensing systems, and heavy-duty applications can require significantly higher throughput than passenger vehicles. The U.S. Department of Energy identifies high-throughput hydrogen dispensing as an important infrastructure requirement for medium- and heavy-duty vehicles. For a container terminal, refuelling capacity should therefore be calculated from the fleet's simultaneous demand, operating shifts, average consumption and available refuelling windows. A useful design objective is to avoid creating a new bottleneck: if ten terminal tractors finish a shift at roughly the same time, the fuel station must be capable of handling that peak demand without creating unacceptable queues. Reference: U.S. Department of Energy – Hydrogen Delivery Roadmap
Retrofitting should begin with an assessment of what can be retained and what must be replaced. For biofuels, much of the existing liquid-fuel infrastructure may remain usable, subject to compatibility checks. LNG and hydrogen require much more substantial changes because storage, transfer, dispensing and safety systems are fundamentally different from conventional diesel infrastructure. A retrofit assessment should examine available land, existing fuel tanks, electrical capacity, traffic flows, drainage, fire protection, emergency access and separation distances. It should also consider whether refuelling can occur without disrupting cargo operations. Hydrogen infrastructure, for example, may require compression, dedicated storage and specialised dispensing equipment, while LNG requires cryogenic storage and associated systems. Retrofitting is therefore not simply a matter of replacing one pump with another. It is effectively a redesign of part of the terminal's energy infrastructure, with the extent of modification determined by the chosen fuel and the operating profile. Reference: U.S. Department of Energy – Hydrogen Infrastructure
Yes, and phased deployment can be particularly useful for container terminals because fuel demand, equipment conversion and infrastructure capacity can grow together. A terminal might initially use mobile deliveries and a limited number of dispensing points before investing in permanent storage and distribution systems. For hydrogen, this could mean starting with delivered compressed or liquid hydrogen before considering larger-scale infrastructure or on-site production. For biofuels, the transition can be simpler because compatible liquid fuels may be introduced using much of the existing infrastructure. A phased approach also allows the terminal to gather operational data on fuel consumption, refuelling patterns, equipment availability and supply reliability before committing to larger infrastructure. However, the initial design should avoid creating stranded assets. Interfaces, land allocation, electrical capacity, safety zones and future expansion requirements should be considered from the beginning. Infrastructure planning should therefore be scalable rather than designed only for the first pilot fleet. Reference: U.S. Department of Energy – H2A Delivery Analysis
The terminal should plan backwards from its expected future energy demand rather than simply from the number of vehicles being converted today. This means estimating fleet size, equipment duty cycles, fuel consumption, operating hours, peak refuelling demand and the expected pace of fleet conversion. Infrastructure should then be checked against future storage capacity, delivery frequency, dispensing throughput, available land and safety requirements. Hydrogen is particularly sensitive to this approach because its delivery pathway can involve production, compression or liquefaction, transport, storage and dispensing, each of which can become a capacity constraint. The IMO's current work on renewable-fuel infrastructure also highlights the need to develop production, transport, storage and bunkering infrastructure together as demand grows. For terminals, the practical lesson is clear: even an initial pilot should be designed with expansion in mind, because rebuilding fuel infrastructure after fleet conversion can be considerably more disruptive than reserving capacity from the start. Reference: IMO – Renewable Fuels and Infrastructure for Net-Zero Shipping
Container terminal managers need safety and productivity. Successful operations target zero accidents and continuous handling. Analyse incidents and share accurate data to improve behavioural safety. Fewer accidents reduce container damage and claims. Base your KPIs on comprehensive records of container movements and vehicle usage. Terminal Tracker offers comprehensive operations planning, yard traffic optimisation through real-time data, and fleet management for true visibility.
Terminal Tracker by Identec Solutions
Alternative fuels can potentially be used across much of a terminal's mobile equipment fleet, but suitability varies considerably by equipment type. Terminal tractors, straddle carriers, reach stackers, forklifts, and other heavy-duty vehicles are the most obvious candidates for hydrogen, LNG or biofuels. Hydrogen fuel cells are particularly relevant to applications requiring electric drive, while hydrogen combustion engines provide another possible pathway. LNG is primarily suited to equipment using suitably adapted internal-combustion engines. Biofuels can be particularly attractive for conventional diesel-powered equipment because certain fuels, notably HVO, can be used as drop-in alternatives subject to manufacturer approval. Stationary equipment and generators can also potentially use alternative fuels. The practical choice depends on power demand, duty cycle, operating hours, refuelling requirements and equipment availability. The IEA's H2Ports project, for example, has demonstrated hydrogen technology specifically in port-handling equipment. Reference: IEA – Hydrogen as a driver for the decarbonisation of shipping
The most fundamental change is that the vehicle becomes electrically driven rather than mechanically driven by a conventional diesel engine. Hydrogen is stored onboard and fed to a fuel cell, which generates electricity for an electric motor. A battery is normally incorporated to manage transient loads and regenerative braking. This changes the vehicle's powertrain, thermal management, control systems and maintenance requirements. It can also improve efficiency because fuel cells can convert hydrogen's chemical energy into electricity more efficiently than conventional internal-combustion engines. The U.S. Department of Energy notes that fuel cells can be two to three times more efficient than internal-combustion engines in transportation applications. For a terminal, however, the relevant question is not simply peak efficiency. Equipment must also deliver the required tractive effort, acceleration, uptime and continuous performance under demanding duty cycles. Reference: U.S. Department of Energy – Hydrogen's Role in Transportation
Hydrogen fuel-cell equipment can provide electric-drive characteristics that differ noticeably from those of diesel machinery. Electric motors deliver torque directly and can provide smooth acceleration, while the fuel cell acts primarily as the energy-conversion system rather than mechanically driving the wheels. This can reduce vibration and noise and potentially improve energy efficiency. The U.S. Department of Energy identifies fuel-cell vehicles as quieter and more efficient than conventional vehicles because electric motors have fewer moving parts and fuel cells can operate more efficiently than combustion engines. However, terminal equipment is not operated like a passenger car. Heavy loads, frequent acceleration, stop-start cycles and long operating hours place demanding requirements on the complete system, including the fuel cell, battery, thermal management and power electronics. Consequently, performance needs to be assessed using the actual terminal duty cycle rather than relying solely on laboratory efficiency figures. Reference: U.S. Department of Energy – Systems Development and Integration: Transportation
Yes, hydrogen fuel-cell systems can be designed for heavy-duty applications, but the complete powertrain must be matched to the equipment's power and duty-cycle requirements. A fuel cell may provide the continuous energy supply while a battery handles rapid changes in power demand, such as acceleration or lifting. This hybrid approach is particularly relevant to terminal equipment because power demand can fluctuate substantially during a work cycle. The U.S. Department of Energy is specifically developing and demonstrating medium- and heavy-duty fuel-cell systems, including applications beyond road vehicles such as off-road equipment. Its programme focuses on durability, thermal management, onboard storage and high-flow fuelling because these factors determine whether fuel cells can meet demanding commercial operating conditions. For terminals, the important performance metrics are therefore sustained power, peak power, acceleration, lifting performance, energy consumption, reliability and availability—not simply the rated output of the fuel-cell stack. Reference: U.S. Department of Energy – Systems Development and Integration: Transportation
LNG-powered heavy-duty equipment generally retains an internal-combustion engine but uses natural gas as the fuel. This means the overall operating concept can remain more familiar to operators and maintenance teams than with a fuel-cell electric vehicle. LNG engines commonly use spark ignition, although other engine architectures are possible. The fuel is stored cryogenically in insulated tanks, and the vehicle requires fuel-system components designed specifically for LNG. The U.S. Department of Energy notes that LNG vehicles are particularly used for heavy-duty applications where longer range is required because LNG has higher energy density than compressed natural gas. However, LNG storage tanks are larger and more complex than conventional diesel tanks, and the engine's performance and fuel consumption depend on the specific engine design and natural-gas quality. LNG therefore represents an evolution of combustion equipment rather than a simple fuel substitution. Reference: U.S. Department of Energy – How Do Liquefied Natural Gas Trucks Work?
Not necessarily, but conventional diesel engines cannot simply be filled with LNG without modification. LNG equipment requires an engine and fuel system designed or adapted to use natural gas. Dedicated spark-ignition engines are one option, while dual-fuel systems can use natural gas together with diesel. Dual-fuel systems can improve fuel flexibility but introduce additional complexity because the vehicle must store and manage two fuels. The U.S. Department of Energy notes that dual-fuel heavy-duty engines can be slightly more fuel-efficient than dedicated spark-ignition natural-gas engines, while also requiring additional fuel-storage and aftertreatment integration. For a terminal considering conversion, the critical question is therefore whether the equipment manufacturer offers an approved natural-gas configuration or whether a qualified retrofit is technically and legally appropriate. Retrofitting should never be treated as a generic engine modification; emissions compliance, safety and reliability all need to be demonstrated. Reference: U.S. Department of Energy – Natural Gas Benefits
Sometimes. The answer depends strongly on the specific biofuel and the equipment manufacturer's approval. Certain renewable diesel fuels such as HVO are chemically similar enough to conventional diesel that they can function as drop-in fuels in approved equipment. Biodiesel is more dependent on blend concentration and equipment compatibility. This makes biofuels fundamentally different from hydrogen and LNG: in suitable applications, the existing engine, fuel tank and distribution system can remain largely unchanged. However, a terminal should not assume that every fuel labelled “biofuel” is automatically compatible. Fuel specification, blend level, seals, hoses, storage conditions and OEM requirements all need to be checked. The U.S. Department of Energy notes that biodiesel blends are available at different concentrations, with B5 generally requiring no special handling compared with conventional diesel, while higher blends may have additional considerations. Reference: U.S. Department of Energy – Biodiesel Blends
HVO and biodiesel are often grouped together as biofuels, but they are technically different fuels. Biodiesel is typically FAME, produced through transesterification, whereas HVO is a hydrotreated renewable hydrocarbon. This distinction matters because HVO can have properties much closer to conventional petroleum diesel and can therefore be used as a drop-in fuel in many applications approved for it. Biodiesel blends, particularly at higher concentrations, can introduce different considerations involving cold-flow behaviour, oxidation stability, storage and material compatibility. For a container terminal, this can make HVO particularly interesting when the objective is to reduce emissions without replacing large numbers of diesel-powered machines. Nevertheless, compatibility must be established for the specific engine and fuel specification rather than assumed from the generic term “renewable diesel”. The simplest conversion is still one that the equipment manufacturer explicitly supports. Reference: U.S. Department of Energy – Biodiesel Basics
Operating range depends on the amount of usable energy carried onboard and the efficiency of the complete powertrain. Hydrogen has high energy content by mass but requires comparatively bulky storage systems, while LNG provides more compact storage than compressed natural gas but still requires dedicated cryogenic tanks. Biofuels generally have energy characteristics closer to conventional diesel, so range changes can be relatively modest. Hydrogen fuel-cell equipment can compensate for its storage characteristics through efficient energy conversion, and hydrogen refuelling can potentially be completed quickly. The U.S. Department of Energy identifies hydrogen's potential for long-distance heavy-duty applications and fast refuelling as important advantages. For terminal equipment, however, range should be defined operationally: how many container moves, operating hours or shifts can a machine complete before refuelling? That measure is more useful than simply comparing kilometres of road range. Reference: U.S. Department of Energy – Hydrogen's Role in Transportation
Yes. The differences depend on the powertrain rather than simply the fuel. Hydrogen fuel-cell equipment using electric motors can deliver high torque from low speed and provide smooth, responsive acceleration. LNG equipment using an internal-combustion engine retains many characteristics of combustion-powered machinery, although the engine calibration and torque characteristics can differ from diesel. Biofuel-powered diesel engines generally preserve the familiar response of the underlying diesel powertrain. This distinction matters in container terminals because equipment frequently accelerates, stops, reverses and handles heavy loads within short distances. A fuel that looks competitive based on energy content may therefore behave differently once converted into mechanical work. Evaluation should include acceleration under load, hill-climbing, lifting cycles, braking, low-speed manoeuvring and repeated transient operation. The DOE's heavy-duty fuel-cell programme specifically highlights transient operation, thermal management and hybridisation as areas requiring validation for commercial applications. Reference: U.S. Department of Energy – Systems Development and Integration: Transportation
Cold weather can affect fuels and powertrains in very different ways. Biodiesel can have poorer cold-flow properties than conventional diesel, depending on its composition and blend, potentially affecting fuel handling and starting. LNG remains a cryogenic liquid, so its storage system is designed around very low temperatures, but the engine and associated systems still have their own cold-weather requirements. Hydrogen fuel-cell systems must manage the behaviour of water and other components during cold starts, making thermal management important. DOE fuel-cell targets explicitly include cold-start performance and operation at low ambient temperatures. For a container terminal in a cold climate, therefore, winter performance should be tested as part of the equipment evaluation rather than treated as a minor seasonal issue. The relevant question is whether the complete machine can reliably start, reach full operating capability and maintain performance during the terminal's lowest expected operating temperatures. Reference: U.S. Department of Energy – Technical Targets for Fuel Cell Systems
Maintenance requirements can change significantly because the powertrain changes. A hydrogen fuel-cell vehicle has no conventional diesel engine, eliminating many components associated with combustion-engine maintenance, while introducing fuel-cell stacks, air and water management, high-voltage electrical systems, hydrogen storage and associated controls. Electric motors also contain fewer moving parts than conventional engines. However, fewer conventional engine components do not mean maintenance-free operation. Fuel-cell durability, thermal management, hydrogen-system inspection and high-voltage safety become important. DOE development programmes specifically address fuel-cell durability, thermal management, onboard storage and system integration because these determine commercial viability in heavy-duty applications. For a terminal, maintenance teams therefore need new competencies rather than simply fewer tasks. Training, diagnostic tools, spare-parts availability and manufacturer support should be included in the equipment decision from the beginning. Reference: U.S. Department of Energy – Fuel Cell Technologies Manufacturing R&D
Yes. LNG-powered equipment retains an internal-combustion engine, but the fuel system introduces components and hazards that are not present in conventional diesel equipment. Cryogenic storage tanks, fuel lines, valves, regulators and gas-management systems require specialised inspection and maintenance procedures. Technicians must understand both the engine and the properties of LNG. Gas detection and leak-management procedures are also important because natural gas can form a flammable mixture with air. The fuel system therefore introduces a different maintenance environment even where the basic engine architecture remains familiar. The U.S. Department of Energy's heavy-duty LNG guidance describes dedicated LNG components and systems, while its natural-gas vehicle guidance emphasises the importance of qualified conversions meeting applicable safety and emissions requirements. For terminals, this means maintenance capability should be established before fleet conversion rather than developed reactively after equipment enters service. Reference: U.S. Department of Energy – Heavy-Duty LNG Vehicle Resource Guide
The comparison should use the terminal's actual operating cycle rather than relying on manufacturer headline specifications. Important measures include energy consumption per operating hour or container move, maximum and sustained power, acceleration under load, operating range, refuelling time, availability, start-up performance, noise, maintenance requirements and performance in different weather conditions. Hydrogen fuel-cell equipment should additionally be evaluated for fuel-cell durability, battery interaction and thermal management. LNG equipment should be assessed for fuel consumption, engine performance and the practical implications of cryogenic fuel storage. Biofuel equipment can often be compared more directly with the existing diesel fleet because the underlying powertrain may remain unchanged. DOE's heavy-duty hydrogen programmes explicitly emphasise real-world validation, durability, operating efficiency, fuelling time and total cost of ownership. The same principle should apply to every alternative fuel: measure productivity per terminal shift, not simply efficiency on paper. Reference: U.S. Department of Energy – Systems Development and Integration: Transportation
Yes, and a mixed fleet may ultimately be more practical than choosing a single fuel for every application. Different equipment has different duty cycles and operating requirements. Biofuel can be attractive for existing diesel machinery where minimal disruption is important. Hydrogen fuel cells may suit high-utilisation equipment where electric drive and rapid refuelling provide operational advantages. LNG can potentially serve applications where combustion powertrains and longer operating ranges are priorities. A mixed fleet does, however, create additional complexity. The terminal may need several fuel-storage and refuelling systems, different maintenance competencies, separate spare-parts streams and different safety procedures. It can also complicate energy management and workforce training. The decision should therefore be based on operational fit rather than technological enthusiasm. A terminal does not necessarily need one fuel for everything; it needs the right powertrain for each equipment duty cycle, while keeping the resulting operational complexity manageable. Reference: U.S. Department of Energy – Systems Development and Integration: Transportation
Work with assets available for specific tasks at given times using Terminal Tracker. Seamless TOS integration enables planning based on ship size and deadlines without conventional complexity. Create plans for the next day or week quickly. When unforeseen changes happen, adapt your operational plan immediately. The Terminal Tracker planning module guides you through the process quickly and easily.
Terminal Tracker by Identec Solutions
A terminal cannot decarbonise its equipment simply by selecting a technically suitable fuel. It needs a reliable supply of that fuel at the required volume, quality and frequency. This is particularly challenging for hydrogen because production, transport, storage and distribution infrastructure is still developing in many regions. LNG has a more established supply chain, but its availability and long-term attractiveness vary by location, while biofuel availability depends on feedstock, production capacity, competing demand and sustainability requirements. The IEA expects clean hydrogen supply chains to expand, but also identifies infrastructure and demand creation as important barriers to scaling the hydrogen economy. For terminals, supply reliability is especially important because fuel shortages can translate directly into equipment downtime. A fuel strategy therefore needs to assess not only today's availability but also whether sufficient supply can realistically be secured throughout the expected lifetime of the equipment. Reference: IEA – Global Hydrogen Review 2025
Alternative-fuel equipment often incorporates additional or entirely different technologies that increase acquisition costs. Hydrogen fuel-cell equipment requires fuel-cell systems, hydrogen storage, power electronics and often batteries. LNG equipment requires cryogenic fuel tanks and dedicated fuel systems. Even where the underlying vehicle is similar to a diesel machine, these additional systems can increase manufacturing and integration costs. The problem is compounded by relatively small production volumes compared with mature diesel equipment, meaning manufacturers have fewer opportunities to spread development and manufacturing costs. The European Commission's Clean Hydrogen Partnership identifies high costs and limited economies of scale as important barriers to hydrogen deployment. For terminals, the relevant calculation should therefore not stop at purchase price. Higher acquisition costs need to be assessed against fuel expenditure, maintenance, productivity, emissions costs, incentives and the expected operating life of the equipment. Reference: Clean Hydrogen Partnership – Hydrogen Valleys
The purchase price is only one component of the economic case for alternative-fuel equipment. A terminal also needs to consider fuel consumption, fuel price, maintenance, infrastructure costs, financing, equipment utilisation, residual value and potentially carbon-related costs. A more expensive hydrogen machine could theoretically become competitive if it has lower energy or maintenance costs and operates at high utilisation. Conversely, a low-cost alternative-fuel machine may produce poor economics if its fuel is expensive or difficult to obtain. The European Commission's Clean Hydrogen Partnership emphasises the importance of reducing both production costs and infrastructure costs to make hydrogen competitive. For terminal operators, total cost of ownership should therefore be calculated over the equipment's expected service life and compared against the incumbent diesel option. Crucially, the calculation should use realistic operating data from the terminal rather than generic assumptions about fuel consumption or utilisation. Reference: Clean Hydrogen Partnership – Strategic Research and Innovation Agenda
Infrastructure can become a substantial part of the investment. Hydrogen deployment may require production or delivery infrastructure, compression, storage, dispensing systems, electrical upgrades and safety equipment. LNG requires cryogenic storage, transfer equipment and gas-handling systems. Even biofuel adoption can require tank modifications, fuel-quality management or additional storage capacity, although the infrastructure requirement is generally much smaller. This creates an important distinction between vehicle investment and system investment. A terminal converting 20 diesel tractors cannot simply multiply the price difference between a diesel and alternative-fuel tractor by 20. It also needs to account for the supporting infrastructure required to keep those vehicles operating. The European Commission identifies infrastructure development as one of the key conditions for scaling hydrogen use. A realistic business case therefore needs to include both fleet conversion and the energy infrastructure required to support it. Reference: Clean Hydrogen Partnership – Strategic Research and Innovation Agenda
The economics of alternative fuels can change significantly with energy prices, production costs, taxes, carbon pricing and supply conditions. Hydrogen is particularly sensitive because its delivered price depends on electricity or feedstock costs, production technology, transport, storage and distribution. Biofuel prices can be affected by feedstock availability and competing demand from other sectors. LNG prices are also exposed to natural-gas market conditions. This uncertainty makes it difficult for terminals to forecast operating costs over equipment lifetimes that may extend for many years. The IEA's analysis of hydrogen highlights the importance of reducing costs and establishing reliable markets as hydrogen deployment expands. For terminal operators, the sensible approach is to model several fuel-price scenarios rather than assume a single future price. The investment decision should remain viable under realistic variations in fuel costs, particularly because fuel expenditure can become a major component of total operating cost. Reference: IEA – Global Hydrogen Review 2025
Alternative-fuel terminal equipment is still a smaller market than conventional diesel machinery, particularly for specialised port equipment. This can limit the number of available manufacturers, models and suppliers and can increase lead times. It can also make procurement more complicated because terminals may have fewer opportunities to compare competing technologies under identical operating conditions. Limited availability can affect spare-parts supply, maintenance support and long-term manufacturer commitment as well. The European Commission has repeatedly identified scaling and industrialisation as important elements in reducing the cost of clean-hydrogen technologies. For terminals, this creates a procurement risk: choosing an immature technology may deliver environmental benefits but create difficulties if the supplier changes its product strategy or exits a market. Equipment availability should therefore be assessed alongside technical performance, not treated as a procurement detail that can be solved later. Reference: Clean Hydrogen Partnership – Strategic Research and Innovation Agenda
This is one of the central challenges of alternative-fuel deployment. Infrastructure tends to be expensive, but its economics improve when utilisation is high. A hydrogen station serving only a handful of vehicles may have a very different cost per kilogram dispensed from one serving a large fleet. The same principle applies to LNG storage and distribution infrastructure. Investing too early can therefore result in underutilised assets and poor returns. Waiting too long, however, can leave the terminal without the infrastructure needed to meet environmental targets or convert its fleet. This creates a classic “chicken-and-egg” problem: equipment deployment depends on infrastructure, while infrastructure investment depends on equipment demand. The IEA identifies infrastructure and demand coordination as important challenges in developing hydrogen markets. Terminals can reduce the risk through phased deployment, modular infrastructure and partnerships with other local fuel users where practical. Reference: IEA – Global Hydrogen Review 2025
Alternative-fuel projects can be affected by changing requirements covering emissions, fuel standards, safety, infrastructure, permitting and reporting. This matters particularly for assets with long lifetimes because today's regulatory assumptions may not remain unchanged throughout the investment period. Hydrogen introduces additional regulatory questions because its production, transport, storage and use involve several different regulatory domains. LNG faces its own safety and emissions requirements, while biofuels are affected by sustainability and fuel-quality rules. The IMO's work on alternative marine fuels illustrates how regulatory frameworks continue to evolve as new fuels enter the market. For terminal operators, regulatory uncertainty creates a risk that infrastructure or equipment designed around one set of requirements may require modification later. Investment planning should therefore include regulatory scenarios and allow sufficient flexibility to accommodate future standards rather than optimising the project exclusively for today's requirements. Reference: IMO – Reducing Greenhouse Gas Emissions from Ships
Government incentives can significantly influence the economics of alternative-fuel projects, particularly during the early stages of market development. Grants, tax credits, carbon-pricing mechanisms and other forms of support can reduce the effective capital or operating cost of low-emission equipment and infrastructure. Hydrogen projects are particularly sensitive to such mechanisms because green hydrogen can currently face a cost disadvantage compared with fossil-based alternatives in many markets. The IEA notes that policy support and demand-side measures are important for accelerating clean-hydrogen deployment. However, incentives should not be treated as guaranteed income over the entire lifetime of a terminal asset. Schemes can change, expire or introduce eligibility conditions. A robust terminal business case should therefore distinguish between the economics with incentives and the underlying economics without them. Incentives can accelerate a viable transition, but they should not be the only reason an investment appears viable. Reference: IEA – Global Hydrogen Review 2025
Yes. Stranded-asset risk exists whenever technology, regulation or fuel markets develop faster than the expected equipment lifetime. A terminal could invest heavily in LNG equipment, for example, only to face increasingly stringent greenhouse-gas requirements that reduce the attractiveness of fossil natural gas. Conversely, hydrogen infrastructure could become difficult to justify if demand develops more slowly than expected or if another technology becomes dominant for a particular application. Biofuel infrastructure generally presents less technology-specific risk where existing liquid-fuel systems remain usable, although long-term fuel availability still matters. The risk is particularly significant for fixed infrastructure because it cannot easily be redeployed. The IEA's analysis of hydrogen repeatedly emphasises the need for coordinated infrastructure development and demand creation. Terminals can reduce stranded-asset risk through modular infrastructure, staged investment and equipment that retains some fuel flexibility where technically feasible. Reference: IEA – Global Hydrogen Review 2025
Residual value can become more uncertain when a machine uses a relatively new or specialised technology. A conventional diesel machine has a large established second-hand market, whereas the resale market for hydrogen fuel-cell or LNG terminal equipment is considerably more dependent on the development of supporting infrastructure and buyer demand. The future value of the equipment can therefore be influenced by factors beyond mechanical condition, including fuel availability, regulatory requirements and technological progress. Biofuel-compatible diesel equipment may face less disruption because the underlying machine remains familiar and can potentially use several liquid fuels. This matters because depreciation is a significant component of total cost of ownership. A terminal comparing technologies should therefore consider not only purchase price and operating cost but also a realistic residual-value assumption. A machine that appears cheaper over its lifetime can become more expensive if its resale value is substantially lower than expected. Reference: IEA – Global Hydrogen Review 2025
Hydrogen projects can become economically difficult during the transition from demonstration to large-scale commercial deployment. Early projects often lack the economies of scale available to mature technologies, while customers may hesitate to commit to large volumes before prices and supply are proven. Infrastructure providers face the opposite problem: they may be reluctant to invest before sufficient demand exists. The resulting gap between technological feasibility and commercially competitive deployment is often described as a “valley of death”. The IEA has highlighted the importance of creating demand, scaling production and building infrastructure to move low-emissions hydrogen technologies towards commercial maturity. For container terminals, this means a technically successful pilot does not automatically prove that a fleet-wide conversion will be economical. A pilot should therefore be designed to generate real operating and cost data that can support the next investment decision rather than simply demonstrate that the equipment can function. Reference: IEA – Global Hydrogen Review 2025
LNG can offer operational and air-quality advantages compared with conventional diesel in suitable applications, but its long-term economic case needs to account for its fossil origin and the direction of climate regulation. LNG infrastructure and equipment can be more mature than hydrogen alternatives, potentially reducing technology risk in the near term. However, methane emissions across the natural-gas supply chain can materially affect its climate performance. The IEA has highlighted methane emissions as a major issue for the natural-gas sector, while IMO climate policy is increasingly focused on reducing greenhouse-gas emissions across shipping. For a terminal making a long-lived investment, the question is therefore not simply whether LNG is cheaper than diesel today. It is whether an LNG machine and its infrastructure will remain economically and environmentally competitive throughout its useful life. This makes LNG a particularly important case where short-term operational benefits must be weighed against long-term regulatory and decarbonisation risk. Reference: IEA – Global Methane Tracker 2025
The principal economic advantage is that some biofuels can reduce emissions without requiring wholesale replacement of existing equipment. Drop-in fuels such as HVO can, where approved by the equipment manufacturer, use existing engines and much of the existing fuel infrastructure. This means the terminal can potentially reduce its carbon intensity while avoiding the capital expenditure associated with replacing an entire fleet. That can make biofuels particularly attractive as a transitional measure while hydrogen or electrification infrastructure develops. The economic benefit depends heavily on the price premium over conventional diesel and the availability of sustainable fuel. Biofuels should therefore be evaluated as an operating-cost decision as well as a capital-cost decision. EMSA notes that the drop-in characteristics of certain biofuels can enable their use without substantial modifications to engines, tanks, pumps or supply systems. For an existing terminal, avoiding those infrastructure and fleet-conversion costs can be a significant advantage. Reference: EMSA – Safe Bunkering of Biofuels
The decision should be based on the terminal's operational requirements and long-term strategy rather than on fuel type alone. Start with the equipment fleet and identify which machines are candidates for conversion, replacement or continued operation. Then compare fuel availability, infrastructure requirements, capital expenditure, energy costs, maintenance, productivity, emissions performance, regulation and residual-value risk. Hydrogen may make sense where high utilisation and long-term zero-emission objectives justify new infrastructure. Biofuels can offer a comparatively low-disruption route for compatible diesel equipment. LNG may fit certain heavy-duty applications but carries greater long-term fossil-fuel and methane-related risk. The most robust approach is usually scenario-based: compare several technology pathways over the expected asset lifetime rather than choosing solely on today's fuel price. The IEA's analysis of clean-energy transitions consistently emphasises the importance of considering infrastructure, policy, technology maturity and demand together. For terminals, the winning solution is ultimately the one that meets environmental targets without compromising operational reliability or economic resilience. Reference: IEA – Global Hydrogen Review 2025
Our position detection system (PDS) delivers real-time location data for semi-automation with Terminal Tracker. Automated job promotion improves accuracy, safety and turnaround time by identifying trucks automatically, eliminating job list searches. Twist-lock control prevents unplanned moves, eliminating lost containers. Control crane usage, box movements and vehicle traffic. Manage terminal access, zones and vehicles—all within one system.
Terminal Tracker by Identec Solutions
Technology & Digital Systems: Terminal Operating Systems (TOS) | Yard Optimisation Algorithms| Reefer Yard Optimisation | OCR, RFID, and IoT Sensor Integration | Digital Twins and Simulation Tools | Predictive Maintenance Systems | Refrigeration and Airflow Systems | Power Supply and Electrical Systems | Reefer Standards, Compliance, and Certification | Predictive Maintenance for Reefers |
Operations & Processes: Vessel Operations | Yard Operations | Gate Operations | Rail and Barge Integration | Transhipment vs. Import/Export Processes | Exception Handling | Chronology of the Cold Chain | Initial Reefer Cargo Conditioning | Pre-Cooling | Reefer Handling at Terminals | Reefer Energy Efficiency and Power Optimisation | Empty Reefer and Return Operations | Reefer Stowage Planning on Vessels | Reefer Flow Management at Terminals |
Equipment, Maintenance & Asset Management: Container Types | Reefer Container Types | Container Identification and Coding | Container Standards and Regulations | Container Handling Equipment (CHE) | Preventive vs. predictive maintenance strategies | Reefer Maintenance, Lifecycle, and Reliability |
Transport & Modalities: Overview of Refrigerated Transport | Reefer Vessels and Maritime Operations | Reefer Stowage | Intermodal and Inland Reefer Transport | Trade Routes and Global Flows | Cold Corridor and Regional Infrastructure | Reefer Flow Management and Balancing |
Reefer Monitoring: Reefer Monitoring Systems and Infrastructure | Reefer Parameters and Data Collection | Reefer Alarm Management and Response | Reefer Data Management and Analytics |
Planning, Optimisation & KPIs: Berth planning and vessel scheduling | Yard planning and Block Allocation | Equipment dispatching strategies | Labour planning and shift optimisation | Peak handling and congestion management | KPI frameworks | Reefer Performance and KPI Measurement |
Cargo & Commodity Handling: Dry General Cargo (Standard Containers) | Dangerous Goods (DG) | Dangerous Goods in Reefers | Out-of-Gauge (OOG) and Project Cargo | Tank Containers | Bulk-in-Container Cargo | High-Value and Sensitive Cargo | Empty Containers | Damaged Cargo and Exception Handling | Reefer Cargo Categories and Industry Applications | Reefer Cargo Preparation and Pre-Loading | Packaging and Protection Technologies | Dangerous and Sensitive Goods Handling in the Cold Chain |
Sustainability & Environmental Impact: Energy Consumption and Electrification | Shore Power (Cold Ironing) | Emissions Tracking | Alternative Fuels | Yard design for reduced travel distances | Waste management and recycling | Sustainable infrastructure development | Energy Efficiency and Power Optimisation in Reefer Handling | Refrigerants and Cooling Sustainability | Carbon Footprint and Emission Tracking | Packaging and Waste Reduction in the Cold Chain | Reefer Infrastructure Efficiency and Green Design |
Safety: Pre-operational safety checks (POSC) | Terminal Equipment safety systems | Personnel safety procedures | Incident reporting and analysis | Safety KPIs and compliance | Training and certification programmes | Risk assessments and hazard identification | Reefer Operational and Equipment Safety | Reefer Cargo Handling and Physical Safety | Chemical and Refrigerant Safety | Training and Continuous Improvement in Reefer Handling |
Human Factors & Organisation: Workforce Skills and Training | Reefer Skills and Training | Change Management | Control Room Operations | Cross-Department Coordination |
Risk Management: Financial Risks | Operational Risks | Strategic Risks | Risk Identification Framework | Operational and Process Risks in Reefer Handling |
Claim Handling: Claim Types | Container Claim Handling Processes | Claim Handling Stakeholders | Reefer Claim Handling |